        Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
         
         
         
         
         
        Glass Tube Flowmeter
        LZB/LZJ series glass rot...
        Glass Tube Flowmeter
        Glass Tube Flowmeter
        LZB-()W/WB series micro ...
        Glass Tube Flowmeter

         


        LUGB series vortex flowmeter [CHENGFENG FLOWMETER] steam measure high accuracy good cost performance
        Product Model:LUGB series
        pdf download:Download

         

        CHENGFENG FLOWMETER for 30 years, has been in the study and progress, learning advanced foreign instrumentation equipment and technology, the introduction of advanced technology, and then based on the research and development of new technology, combined with the requirements of customers innovative products that meet customer needs, meet the requirements of customers, the pursuit of perfect quality, technical breakthroughs.

        Working Principle

         

        Non-streamline vortex-maker be set in fluid(anti-flow part),then two regular vortex would be come out,from two sides of the vortex-maker in turn,so this kind of vortex be called as Karman vortex street,Fig.1 as follow.

            

        vortex-1.jpg

        Vortex is not flowing symmetrically under vortex-maker set.As if,set frequency of vortex is f,the speed of test medium is V,inlet face width of vortex-maker is d,Past part diameter is D,as the principle of Karman vortex street,as follow:

        f=St×v/d

        In the formula:

        St-Jack straw Hal number;

        f-frequency product by single side vortex;

        v-flowrate;

        d-diameter.

        So,check the separate frequency of Karman vortex street to know the instant capacity(flow).among,Strouhal number(St)is dimensionless number, Fig.2 Show the relation of,Strouhal number(St)&Reynolds number(Re).

         

        vortex-2.jpg

                                                                                                                      Fig.2

         

         Straightness part in curve(St=0.17),free frequency & flow rate of vortex is direct ratio,it means flow sensor range.So just check out frequency (f),we can get the flow rate inside pipe,then as the flow rate(V)to take volume flow,the ratio record of impulse& volume,called as(K),as following:

         

                              K=N/Q(1/m³)            

         

        Model:K=instrument constant(1/m³).

                  N=impulse number

                Q=volume flow(m³)

         

        Technical Parameter

         

        vortex-3.jpg

         

        Outline Size

         

        Full Package Type Installing Size

         

        vortex-4.jpg

         

         

        Plug-in Type Installing Size

         

        vortex-5.jpg

         

        Type Selection

         

          1.Model selection table of vortex street flow meter(JB/T9294-1999 standard)

        vortex-6.jpg

         

           2. Table of comparisons sensor drift diameter

        vortex-7.jpg

        Break the routine, meet more customer requirements, customized for clients of various kinds of non-standard type flowmeter, it is a kind of ability, is also a kind of attitude.Let the customer buy satisfied products, let customers get the perfect service that is our attitude.

         

         

         

         

        Attention of  preventive maintenance of vortex flowmeter:
        1. The sensors have no moving parts, need not often maintenance.When the measured medium is not pure or have sediment, according to the actual situation, regular cleaning the sensor.
        2. Maintenance sensor, especially protect the vortex occurred body and probe body.Did not make clear the probe body fault may, at the time of free disassembly, so as not to damage the probe or destroy sealing body, make the sensor produces leakage phenomenon.
        3. The failure, we should first check the power supply is correct, whether fluid condition changes, such as fault cannot be solved, please contact the factory.
        4. The sensor calibration cycle for two years.



        ? 2012 Changzhou Chengfeng Flowmeter Co.,Ltd All Rights Reserved   Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
        Design by Lingdong Internet  Switchboard:86-519-85503558,86-519-85503688  Fax:86-519-85505269,86-519-85503588-8008
        Friendly Links:成豐儀表阿里巴巴店鋪    新浪    
        主站蜘蛛池模板: 国产精品中文第一字幕| 久久天天躁狠狠躁夜夜躁2o2o| 亚洲精品二| 九九免费视频| 亚州AV成人无码久久精品| 亚洲无线一二三四区手机| 日本三级吃奶头添泬无码苍井空| 91丝袜| 九九热在线视频观看最新| 亚洲偷自拍国综合| 一区二区三区日本久久九| 国产美女69视频免费观看| 在线无码国产精品亚洲а∨| 亚洲人妻在线一区二区| 国产精品老熟女露脸视频| 亚洲激情小说| 成人综合精品| 午夜福利一区二区91| 熟妇好大好深好满好爽| 人妻性奴波多野结衣无码| 精品人妻一区二区三区四区在线| 亚洲国产系列一区二区三区| 线在女熟产国| 国产精品国产精品一区精品| 日本一区不卡高清更新二区| 国产又爽又黄无码无遮挡在线观看| 亚洲av熟女| 国产91精品调教在线播放| 亚洲中文有码在线观看| 麻豆国产精品一二三在线观看| 污网址在线观看| 国产学生裸体无遮挡免费| 欧美成人综合| AV中文天堂| 国产欧美精品一区二区色综合| 国产老熟妇| 国产精品老熟女免费视频| 亚洲色情在线| 欧美喷潮最猛视频| 欧美精品亚洲精品日韩专| 在线a人片免费观看|